Articlexpo
Search:    Main :> About Us :> Privacy :> Terms of Use :> Add Url :> Submit Article   
 

Titanium Promise Rings

The system of promise rings may seem to be something that has been started in modern times. However, ... - Richard Romando
 

Lightweight Neck Ties

Lightweight neck ties comes in various forms such as plain ties, boy ties, clip on ties and much mor ... - OliviaAndrews
 

SureChic expands business onlien the old fashion way: word of mouth! 85% discounts offered at www.surechic.com for a limited time.

SureChic expands beyond the doors of its small Atlanta boutique by offering their authentic designer ... - Surechic.com
 
 

Used Exercise Equipment

Used exercise equipment is widely available on the market today. New exercise machines cost several ... - Jennifer Bailey
 

The Progression Of The Treadmill Stress Test

The reliability and/or validity of the treadmill stress test is perhaps the most significant reason ... - Kevin Urban
 

Civil War Uniforms: Keep Your Jean Cloth from Unraveling

AHHHH! How to keep jean cloth from unraveling? - Paula McCoach
 

Get More With Less Work: Higher Auction Prices On eBay Can Be Yours

If you want to increase your profits on eBay then it is time to take your hobby to a professional bu ... - Chris Ryerson
 

Choosing the Right Pillow for Proper Back Support

Learn how different types of pillows can provide proper spinal support, eliminate headaches, back an ... - Charles Kassotis
 
 

Main » Shopping Online » Electrical Appliances
 

Air Compressors and Energy

 
Author: James Hunt
 

You may discover that, even though you are using a smaller amount of compressed air, the electric energy consumed does not diminish proportionately and occasionally does not lessen at all. In one case, after the leaks were fixed, the system pressure rose and the electric power consumed increased. A frequent reason for this result is that the delivery controls are just not responding to system demand.

The two most effective ways to run an air compressor are at full load and off. Unloading controls that operate continuously restrict the air delivered to the system. This is always a compromise that is never as efficient as operating at full load. A great deal has been written about how capacity controls operate. Now it is time to look at some of the common problems that affect their ability to perform.

When working effectively, unloading controls do several things. They match supply to demand and minimize over-pressure while maintaining the minimum acceptable pressure. They make input power proportional to air flow demand. They turn off and reactivate air compressors as required.

The working pressure band is the pressure range the control can span from fully loaded flow to fully unloaded. Well-planned systems hold as narrow a band as possible. The first control type is automatic start/stop that automatic starts and stops the electric motor or driver. A pressure switch shuts off the motor at the upper pressure limit and restarts the motor at a lower pressure. Heat buildup in AC electric motors limits the number of starts allowed over a given time, particularly for motors larger than 10 to 25 hp.

Unloading with continuous-run controls lets the motor run while the compressor is unloaded. This matches supply to demand, usually on the basis of system pressure. Step controls are also called load/no-load or two-step that keeps the inlet either fully open or fully shut. The unit is at full load from the preset minimum pressure point to the preset maximum pressure.

The basic performance is fully loaded or full flow up to the preset maximum pressure when the air flow shuts off completely. The unit then idles at no flow until pressure falls to the preset minimum when the unit goes to full flow. In this control, the compressor runs at its two most efficient modes"full load and full idle.

When controls, piping or storage is misapplied, not only is there little or no power savings, but short cycling can result. Too much backpressure in the interconnecting system can lead to short cycling or ineffective unloading. A duty cycle of 20 seconds "on" and 20 seconds "off" damages equipment and shortens the life of bearings, coolers, motors and separators.

 
 
 

Related Articles

 
Filterless Air Purifiers: What You Need To Know
 
Incline Treadmills
 
Learn How To Find Great Deals When Using eBay
 
Sterling Silver Jewelry: From Humble Beginnings to Exquisite Craftsmanship
 
Diamond Wedding Ring Guide: Tips And Advice For Choosing Your Ring
 
The Importance of Sauna Heaters
 
Nose Piercings
 
Water Rower -- Just Like a Cruise Down the River Without Getting Wet
 
How To Create An eBay Sales Page
 
Silver Jewelry Alchemy And The Number 7 - Part I The 7 Metals Of Antiquity
 
 
 
Add URL
 
 

Teens & Children

 

Food & Recipe

 

Automobiles

 

Adventure & Sports

 

Society & Communities

 

Hotels & Travel

 

Science & Research

 

Computers & Networking

 

Self Help

 

Government & Politics

 

Employment & Careers

 

Music & Entertainment

 

Shopping Online

 

Culture & Art

 

Medicine & Treatment

 

Events & News

 

Lifestyle & Fashion

 

Business & Commerce

 

Family & Home

 

Estate & Realty

 

Banking & Finance

 

Education & Learning

 

Online & Indoor Games

 

Fitness & Health


 
Main :> Privacy :> Terms of Use  
Copyright © 2008 www.articlexpo.com